All Articles
Commercial Saunas for Gyms, Hotels and Resorts in Thailand
The sauna in a private garden is used four or five times a week by the same two…
Free Delivery · 1–2 Yr Warranty · After-sales Support
This chiller is designed for ice bath and plunge pool use, handling larger water volumes with a cooling range of 0°C to 42°C and a minimum operating temperature of −1°C. An industrial-grade compressor, dual precision filtration, and a 188W circulation pump (40 L/min) keep water clean and at a consistent set temperature without manual intervention.
price updates live
Add multiple products, then email yourself the full quote or checkout.
Have more questions? Chat with us
Both cooling and heating functions are built in, making the unit practical year-round. The 7-inch full-colour LCD touchscreen displays real-time water temperature, operating mode and equipment status at a glance, while Wi-Fi connectivity via the Tuya app allows remote control and scheduling from a phone.
The 304 stainless steel honeycomb heat-dissipation panel resists corrosion, and IPX4 weatherproofing means the unit can be placed outdoors. Four load-bearing castors with a 360° swivel and brake lock make it easy to reposition on any surface. A built-in ozone disinfection system (up to 50 mg/hr) reduces the need for chemical water treatment.
Lead times vary by stock availability — confirm current lead time at the time of order. The unit ships fully assembled in foam, carton, and wooden box packaging.
Delivery is to kerbside or ground-floor access. The chiller weighs 63 kg; ensure adequate assistance or equipment is available for unloading and placement. The castors allow the unit to be wheeled into its final position once on a flat surface.
For upper-floor or difficult-access installations, arrange additional lifting assistance prior to delivery. Notify us of any access restrictions (narrow gates, stairs, lifts) at the time of order so logistics can be planned accordingly.
The chiller arrives largely pre-assembled and requires only plumbing connection to the ice bath or plunge pool — no specialist refrigeration or electrical trade is needed for the water hookup.
Connect the two included water pipes to the aluminium alloy inlet and outlet ports on the rear of the unit using the included adapter interface. Wrap threaded connections with the included waterproof tape for a leak-free seal. Route the hoses to the tub and ensure they are secured before powering on.
Plug the unit into a standard AC 220–240V 50/60Hz power outlet rated for at least 13 A (standard model) or 15 A (T3 model). A 100–240V wide-voltage adapter is available on request for other voltage regions. No hardwiring is required under standard installation. Ensure the outlet is protected by an appropriate RCD/safety switch as recommended for any appliance used near water.
Download the Tuya app on iOS or Android and follow the included Remote Connection Instruction Manual to pair the chiller to your Wi-Fi network. All temperature control and scheduling can then be managed from the app or via the on-unit touchscreen.
If an electrical item stops working within the warranty period, we’ll send you a replacement free of charge.
16-month manufacturer's warranty against defects in materials and workmanship. Coverage details should be confirmed with the retailer at point of sale.
Filters
- Inspect the dual precision filter elements every 2–4 weeks depending on usage and water quality. Unscrew the filter housing using the included filter bottle wrench, rinse the element under clean water, and refit. Replace with the supplied spare when the element is visibly degraded.
- The extra small inline filter should be checked monthly; rinse or replace as needed.
Water
- Drain and refill the connected tub every 4–6 weeks under normal household use, or more frequently in commercial or high-use settings.
- The ozone disinfection system (up to 50 mg/hr) reduces the need for chemical additives but does not eliminate the need for periodic water changes.
- Use the included condensate drain nozzle to fully drain the unit before extended storage or transport.
Exterior
- Wipe the stainless steel and powder-coated panels with a damp cloth. Avoid abrasive cleaners that could scratch the finish.
- Keep the cooling fan intake clear of debris, leaves and dust, particularly in outdoor installations.
General
- Do not operate the chiller without water flowing through it; dry running will damage the pump and heat exchanger.
- Check hose connections for leaks at each seasonal start-up. Wrap threaded fittings with the included waterproof tape if weeping is observed.
- Store indoors or cover the unit if it will not be used for an extended period in harsh weather.
Stock items can be returned within 7 days of delivery in resalable condition. Custom and made to order items cannot be returned once production has begun. Faulty goods are repaired, replaced or refunded at our cost.
Tell us where to send it. We'll email your quote with all the products and options you've selected.