Filters
- Inspect the dual precision filter elements every 2–4 weeks depending on usage and water quality. Unscrew the filter housing using the included filter bottle wrench, rinse the element under clean water, and refit. Replace with the supplied spare when the element is visibly degraded.
- The extra small inline filter should be checked monthly; rinse or replace as needed.
Water
- Drain and refill the connected tub every 4–6 weeks under normal household use, or more frequently in commercial or high-use settings.
- The ozone disinfection system (up to 50 mg/hr) reduces the need for chemical additives but does not eliminate the need for periodic water changes.
- Use the included condensate drain nozzle to fully drain the unit before extended storage or transport.
Exterior
- Wipe the stainless steel and powder-coated panels with a damp cloth. Avoid abrasive cleaners that could scratch the finish.
- Keep the cooling fan intake clear of debris, leaves and dust, particularly in outdoor installations.
General
- Do not operate the chiller without water flowing through it; dry running will damage the pump and heat exchanger.
- Check hose connections for leaks at each seasonal start-up. Wrap threaded fittings with the included waterproof tape if weeping is observed.
- Store indoors or cover the unit if it will not be used for an extended period in harsh weather.